KPA Ku-Band Indoor Solid-State Power Amplifier
Revision 1
Appendix B
MN/KPA.IOM
B–4
B.3.1
Redundancy Kit Control Cabling
For either a 1:1 or a 1:2 redundant system, two control cable assemblies are required for setup as
shown in
Figure B-3
. Other RF coaxial cables and waveguides are required as shown in
Figure B-4
.
Figure B-3. KPA Redundancy System – Control Cabling Schematics
The redundant loop cable used for interconnection of the KPAs via their
J4
REDUNDANT
LOOP
connectors, as shown in
Figure B-3
and
Figure B-4
, has the following characteristics:
•
The cable assembly is not a “straight through” cable.
•
The cable assembly is labeled “
BACKUP
” on one end, and “
KPA#1
” on the other end.
•
The cable assembly is wired so that, when connected to two KPAs, one KPA will
automatically configure itself as the Backup Controller and the other KPA will automatically
configure itself as the ‘Primary KPA’.
•
The backup KPA communicates to the primary KPA via a serial interface that is also
provided by this cable assembly. This interface is used by the Backup KPA to acquire
configuration information from KPA #1. This interface additionally provides the link for
virtual addressing as described in this manual in
Appendix C. REMOTE CONTROL
.
•
Also included in this cable assembly are summary fault relay contacts that are used by the
backup KPA as an input to its switching logic.
For 1:2 redundancy systems, note that the functionality described for the 1:1 cable assembly also
applies to the 1:2 cable assembly; the only difference is that there is now a third connector, labeled
“
KPA#2
”, daisy-chained onto the cable assembly. When a third Comtech EF Data KPA is
connected via this cable assembly, it will automatically configure itself as ‘Primary KPA #2.’
A second cable assembly – a six-wire assembly – connects the Backup Unit’s
J7 RF SWITCH
connector to the Waveguide Switch.
1:1 System Control Cabling
1:2 System Control Cabling
Summary of Contents for KPA series
Page 30: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Installation MN KPA IOM 2 4 Notes...
Page 84: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix A MN KPA IOM A 6 Notes...
Page 124: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix C MN KPA IOM C 30 Notes...
Page 126: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...