![Comtech EF Data KPA series Installation And Operation Manual Download Page 21](http://html1.mh-extra.com/html/comtech-ef-data/kpa-series/kpa-series_installation-and-operation-manual_2648386021.webp)
Ku-Band Solid-State Power Amplifier
Revision 1
Introduction
MN/KPA.IOM
1–5
1.3 KPA Specifications
1.3.1 KPA-020IN Specifications
Parameters
Specifications
Input
Level -10dBm
Typical
Impedance
50
Ω
Noise Figure
10 dB Typical, 15 dB max @ max gain
VSWR
1.25: 1 maximum
Connector SMA
Female
Output
Frequency
14.0 to 14.5 GHz
Power
42.5 dBm minimum @ 1 dB Compression
Mute 60
dB
VSWR 1.25:1
maximum
Connector WR75G
Waveguide
Gain
Linear
50 dB minimum, 53 dB Typical
Adjust
20 dB in 0.25 dB steps
Fill Band
±
0.75 dB
Per 40 MHz
±
-0.25 dB
0 to +50
°
C (32 to 122
°
F)
±
0.75dB
Third Order Modulation
Intercept
+56.5 dBm minimum, 59.0 Typical
Products
-25 dBc max, -30 dBc typical @ 3 dB total
backoff from rated P1dB (two tones,
Δ
f+MHz)
AM to PM Conversion
Output
2.0 degrees typical
3.0 max @ 42.5 dBm
Group Delay (per 40
MHz)
Linear
±
0.03 ns/MHz
Parabolic
±
0.0025 ns/MHz
2
Ripple
1.0 ns Peak-to-Peak
Front Panel
Display
24 x 2 LCD
Data Entry
Cursor Control Keypad (6 keys)
Output Sample
Type N female, 50
Ω
, –40 dBc
Input Sample
Type N female, 50
Ω
, –20 dBc
Remote Control
COM Port
EIA-232 or EIA-485
Protocol ASCII
Alarms
Summary Fault
Form C
LEDs
Power On
Green
Fault Red
Stored Fault
Red
TX On
Yellow
Online Yellow
Remote Yellow
Mechanical
Envelope
3.5H x 19W x 24D inches
(8.89H x 48.26W x 60.96D cm)
Weight TBD
Environmental
Temperature Operating
0 to 50
°
C (32 to 122
°
F)
Storage
–40 to 70
°
C (–40 to 158
°
F)
Humidity Operating
10 to 95% Noncondensing
Storage
0 to 100% Noncondensing
Altitude Operating
15, 000 ft MSL
Storage
50, 000 ft
Shock
Normal Commercial Shipping and Handling
Power Requirements
VAC
90 to 135 or 180 to 270 VAC, 47 to 63 Hz
400W (Auto Select)
Summary of Contents for KPA series
Page 30: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Installation MN KPA IOM 2 4 Notes...
Page 84: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix A MN KPA IOM A 6 Notes...
Page 124: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix C MN KPA IOM C 30 Notes...
Page 126: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...