![Comtech EF Data KPA series Installation And Operation Manual Download Page 75](http://html1.mh-extra.com/html/comtech-ef-data/kpa-series/kpa-series_installation-and-operation-manual_2648386075.webp)
KPA Ku-Band Indoor Solid-State Power Amplifier
Revision 1
Ethernet Management
MN/KPA.IOM
6–15
Redundancy Mode
This
read-only
section provides the following information:
•
The active system operating status is identified as
ON
or
OFF
(when
OFF
, the
configuration sections that follow on this page are not accessible).
•
The active operating unit – i.e., the Primary KPA or Backup KPA – is identified.
•
The active redundancy configuration –
1:1
or
1:2
– is identified.
Automatic/Manual Mode (1:1 or 1:2 Redundancy)
Use the provided drop-down menu to select the backup operation mode as
Automatic
or
Manual
.
Priority Select (1:2 Redundancy only)
Use the provided drop-down menu to select the desired Backup KPA as
SSPA#1
or SSPA#2
.
Note that, for 1:1 configurations, the priority unit number is always fixed as SSPA#1.
Once the desired operational settings have been selected for the operating mode and backup
priority (1:2 redundancy only), click
[Change Redundancy Config]
as needed to save these
settings.
Backup Mode (1:1 or 1:2 Redundancy, Manual Mode only)
When Automatic Mode has been selected as the Operating Mode, this section of the
Redundancy page is inaccessible.
Use the provided drop-down menu to force
SSPA#1
or, for 1:2 redundancy only,
SSPA#2
to
replace the active operating KPA as the primary unit.
Note that, for 1:1 configurations, the Backup KPA is always fixed as SSPA#1.
Once the desired Backup KPA has been selected, click
[Change Backup Mode]
to take the
primary unit
OFFLINE
, and take the selected Backup KPA
ONLINE
.
Summary of Contents for KPA series
Page 30: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Installation MN KPA IOM 2 4 Notes...
Page 84: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix A MN KPA IOM A 6 Notes...
Page 124: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix C MN KPA IOM C 30 Notes...
Page 126: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...