KPA Ku-Band Indoor Solid-State Power Amplifier
Revision 1
Connectors and Pinouts
MN/KPA.IOM
3–8
3.4
Power / Ground Connections
3.4.1
Alternating Current Prime Power Switch and Connector
The On/Off prime power switch is located on the rear of the chassis adjacent to
the prime power input connector. The circuit breaker is rated for 30 Amps.
A standard, detachable, non-locking, 3-prong power cord (IEC plug) supplies
the Alternating Current (AC) power to the unit via the prime power input
connector. Note that the specification for the power source is specific to the
unit as follows:
•
For KPA-020IN only – 90 to 135 VAC, 47 to 63 Hz
•
For KPA-040 only – 90 to 270 VAC, 47 to 63 Hz
•
For KPA-080/-100 only – 180 to 270 VAC, 47 to 63 Hz
3.4.2
Chassis Ground Connector
PROPER GROUNDING PROTECTION IS REQUIRED: The installation instructions
require that the integrity of the protective earth must be ensured and that the
equipment shall be connected to the protective earth connection at all times.
Therefore, it is imperative during installation, configuration, and operation that the
user ensures that the unit has been properly grounded using the ground stud
provided on the rear panel of the unit.
A #10-32 stud is provided for connecting a common chassis ground among
equipment.
Note:
The AC power connector provides the safety ground.
Summary of Contents for KPA series
Page 30: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Installation MN KPA IOM 2 4 Notes...
Page 84: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix A MN KPA IOM A 6 Notes...
Page 124: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix C MN KPA IOM C 30 Notes...
Page 126: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...