KPA Ku-Band Indoor Solid-State Power Amplifier
Revision 1
Ethernet Management
MN/KPA.IOM
6–14
6.5.4.3.3
Config | Redundancy page
IMPORTANT
Comtech EF Data’s KPA family of SSPAs are designed to automatically sense
and configure into Redundancy Mode when the redundant loop cable is
connected between the two (i.e., 1:1) or three (i.e., 1:2) KPAs comprising the
redundant subsystem.
The designation of each KPA in a redundant subsystem is determined
automatically via the redundancy interface cable connected – polling on the
dedicated redundancy bus will not begin until the redundancy loop cable is
connected.
Redundancy page in Automatic Mode
Redundancy page in Manual Mode
Redundancy page in Standalone Configuration (no redundant units recognized by system)
Figure 6-7. Config | Redundancy page
The ‘
Config | Redundancy
’ page (
Figure 6-7
) is used to control the operational parameters for
redundant operations. The active Redundancy Mode is identified on this page as
1:1
,
1:2
, or
OFF
, and the appearance of the page itself varies depending on its Operating Mode.
Summary of Contents for KPA series
Page 30: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Installation MN KPA IOM 2 4 Notes...
Page 84: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix A MN KPA IOM A 6 Notes...
Page 124: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix C MN KPA IOM C 30 Notes...
Page 126: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...