![Comtech EF Data KPA series Installation And Operation Manual Download Page 32](http://html1.mh-extra.com/html/comtech-ef-data/kpa-series/kpa-series_installation-and-operation-manual_2648386032.webp)
KPA Ku-Band Indoor Solid-State Power Amplifier
Revision 1
Connectors and Pinouts
MN/KPA.IOM
3–2
Table 3-1. KPA Interface Connectors Summary
Connector Group
Ref
Des
Name
Connector Type
Function
RF
Sect. 3.2
J1
KPA-020IN: RF IN
KPA-040: Tx IN
KPA-080
KPA-100
Type ‘SMA’ Female
RF Input
J2 RF
OUT
WR75G
Waveguide
Flange
RF Output
Utility
Sect. 3.3
N/A
SAMPLE | INPUT
Type ‘N’ Female
Front Panel –20 dBc and –40 dBc test
sample ports
N/A
SAMPLE | OUTPUT
J4**
REDUNDANT LOOP
19-pin Circular Conn
Unit-to-Unit Redundant Connection
J5 DISCRETE
CONTROL
19-pin Circular Conn
User ISSPA M&C
J8*
10/100 ETHERNET
RJ-45 female
CAT5 10/100 BaseT Management and
Data
J9A*
EXT REF IN
BNC Female
External Reference Input
J9B*
EXT REF OUT
BNC Female
External Reference Output
J7**
RF SWITCH
10-pin Circular Conn
Waveguide Switch Interface
J6
COM1
9-pin Type ‘D’ male
Serial Remote Comms Interface
(EIA-232 or EIA-485)
Power/Ground
Sect 3.5
J3
AC IN
See Sect. 3.5.1
Chassis prime power input
N/A
(Ground)
#10-32 stud
Common chassis ground
Notes:
1.
* KPA-040/-080/-100 units only (not provided on the KPA-020IN).
2.
** Used in redundant operations only. See
Appendix B. KPA REDUNDANT OPERATIONS
for further information about use of the KPA in 1:1 or 1:2 redundant systems.
Summary of Contents for KPA series
Page 30: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Installation MN KPA IOM 2 4 Notes...
Page 84: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix A MN KPA IOM A 6 Notes...
Page 124: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix C MN KPA IOM C 30 Notes...
Page 126: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...