KPA Ku-Band Indoor Solid-State Power Amplifier
Revision 1
Appendix C
MN/KPA.IOM
C–12
Parameter Type
Command
(Instr Code and
Qualifier)
Arguments for
Command or
Response to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes, i.e., ASCII codes between 48 and 57)
Query
(Instr Code and
Qualifier)
Response to Query
(Target to controller)
Mute State
MUT=
1 byte,
value of 0,1
Command or Query.
Mute the unit, where:
0 = Disabled,
1 = Enabled
Example: MUT=1
MUT?
MUT=x
(same format as
command arguments)
Number of
Unread stored
Events
N/A
3 bytes, numerical
Query only.
Returns the number of Stored Events which remain unread, in the form xxx.
Example reply: NUE=018
NUE?
NUE=xxx
(see Description of
Arguments)
Part Number
N/A
Various 1-96 bytes,
alpha-numeric
Query only.
Returns the Comtech EF Data part number of the unit. This part number is the unit’s
DOTCODE at the time it was manufactured. The DOTCODE may be up to 96 printable ASCII
characters long.
Example: <1/PNM?’cr’
>0001/PNM=HPODC0.350WRSW00’cr’’lf’
PNM?
PNM=x….x
(see Description of
Arguments for return
string)
Priority Select
PRI=
1 byte,
value of 1, 2
Command or Query (backup unit only).
This command allows the user to assign priority when operating in a 1:2 redundant subsystem.
This command provides arbitration in the event that both primary KPAs are faulted
simultaneously.
Example: PRI=1
PRI?
PRI=x
(same format as
command arguments)
Retrieve
Alarm Status
N/A
variable length, alpha
numerical
Query only.
Used to Query the Alarm status of the unit.
Example: <0001/RAS?
>0001/RAS=
+28=FT
+15=OK
+7.5=OK
+5=OK
-5=OK
RF_PS1=OK
RF_PS2=xx
TEMP1=OK
TEMP2=xx
LTEMP=xx
SHTD=OK
FAN1=OK
FAN2=OK
BUCLD=OK
XRFLD=OK
TRMST=YS
If it is not applicable, it will display xx.
FT – fault AL – alarm MS – masked YS – yes
RAS?
RAS=x….x
(see Description of
Arguments)
Summary of Contents for KPA series
Page 30: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Installation MN KPA IOM 2 4 Notes...
Page 84: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix A MN KPA IOM A 6 Notes...
Page 124: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix C MN KPA IOM C 30 Notes...
Page 126: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...