![Comtech EF Data KPA series Installation And Operation Manual Download Page 122](http://html1.mh-extra.com/html/comtech-ef-data/kpa-series/kpa-series_installation-and-operation-manual_2648386122.webp)
KPA Ku-Band Indoor Solid-State Power Amplifier
Revision 1
Appendix C
MN/KPA.IOM
C–28
Packed Utility Status
Packed Utility Status:
Confirmation:
<DEV/PACRUS_'cr'
>DEV/PACRUS_abbcdeeff'cr''lf']
Where:
a = COM1 Mode; 0 =RS-232,
1 = RS-485-2; 2 = RS-485-4
bb = Address in Hex (01 to FF)
c =
0 if Baud Rate = 9600
1 if Baud Rate = 4800
2 if Baud Rate = 2400
3 if Baud Rate = 1200
4 if Baud Rate = 300
d = 0 if Parity Even, 1 if Parity Odd
ee = LCD Contrast (0 to 30)
ff = LCD Brightness (0 to 30)
Packed Alarm Status
Packed Alarm Status:
Confirmation:
<DEV/PACRAS_'cr'
>DEV/PACRAS_abcdefghijkl'cr''lf']
Where:
a = 1 if +28 Fault, else 0
b = 1 if +12 Fault, else 0
c = 1 if –12 Fault, else 0
d = 1 if + 5 Fault, else 0
e = 1 if – 5 Fault, else 0
f = 1 if + 9 PS#1 Fault, else 0
g = 1 if + 9 PS#2 Fault, else 0
h = 1 if TEMP Fault, else 0
I = 1 if SHTD Fault, else 0
j = 1 if FAN1 Fault, else 0
k = 1 if FAN2 Fault , else 0
l = 1 if PROC Fault, else 0
C.7.5 Old Stored Alarms
Up to 100 alarms are date/time stamped and stored in memory as they occur. The alarm entry also is updated with its date/time of clearance. The
entry remains in memory until it is removed by command.
Total Stored Alarms
Retrieve Total Alarms:
Confirmation:
<DEV/TSA_'cr'
>DEV /TSATOTAL :nnn'cr'
LAST:hh:mm:ss mm/dd/yy'cr''lf']
This command retrieves the total number of stored alarms and the
time and date of the most recent alarm.
Clear All Stored
Alarms
Clear Alarms:
Confirmation:
<DEV/CAA_YES'cr'
>DEV/CAA_CLEARED'cr''lf']
List All Alarms
List All Alarms:
Confirmation:
<DEV/LAA_'cr'
>DEV/LAA'cr'
xxx yyyyyyyyyyy hh:mm:ss mm /dd/yy'cr'
xxx yyyyyyyyyyy hh:mm:ss mm/dd/yy'cr'
xxx yyyyyyyyyyy hh:mm:ss mm /dd/yy'cr'
xxx yyyyyyyyyyy hh:mm:ss mm/dd/yy'cr'
xxx yyyyyyyyyyy hh:mm:ss mm /dd/yy'cr'
xxx yyyyyyyyyyy hh:mm:ss
mm/dd/yy'cr''lf']
Where :
xxx = stored fault number
yyyyyyyyyyy = fault description
hh:mm:ss = fault time
mm/dd/yy = fault date
Summary of Contents for KPA series
Page 30: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Installation MN KPA IOM 2 4 Notes...
Page 84: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix A MN KPA IOM A 6 Notes...
Page 124: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix C MN KPA IOM C 30 Notes...
Page 126: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...