KPA Ku-Band Indoor Solid-State Power Amplifier
Revision 1
Appendix C
MN/KPA.IOM
C–8
C.6.1 Remote Commands and Queries (FW Version 2.X.X and Higher)
Parameter Type
Command
(Instr Code and
Qualifier)
Arguments for
Command or
Response to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes, i.e., ASCII codes between 48 and 57)
Query
(Instr Code and
Qualifier)
Response to Query
(Target to controller)
Auto Fault
Recovery
AFR= 1
byte,
value of 0, 1
Command or Query.
The SSPA output will automatically be muted in the event of detected fault. If auto fault
recovery is enabled, it will cause the output to go active (un-mute) if all faults are cleared. If
disabled, the output will remain muted even if all faults are cleared.
AFR?
AFR=x
(same format as
command arguments)
RF Power
Amplifier State
AMP= 1
byte,
value of 0, 1
Command or Query.
Turns ON or OFF the RF power amplifiers.
0 = Off
1 = On
Example: AMP=1
AMP?
AMP=x
(same format as
command arguments)
Attenuation
ATT= 5
bytes,
numerical
Command or Query.
Valid attenuation level, in dB, at 0.25-dB step size as factory default.
Example: ATT=12.25
ATT?
ATT=xx.xx
(same format as
command arguments)
Clear All Stored
Events
CAE= None
Command
only.
Instructs the KPA to clear all Stored Events
This command takes no arguments.
Example: <1/CAE=’cr’
N/A
N/A
Concise
Alarm Status
N/A
variable length, alpha
numerical
Query only.
Used to Query the Alarm status of the unit.
Example: <0001/CAS?
>0001/CAS=a;b;c;d;e;f;g;h;i;j;k;l;m;n;o;’cr’’lf’ where:
0 = OK, 1 = Fault, 3 = Not Applicable, 4 = Alarm, 5 = Masked
a = 28V Power Supply
b = 15V Power Supply
c = 7.5V Power Supply
d = 5V Power Supply
e = -5V Power Supply
f = 9V or 10V RF Power Supply 1
g = 9V or 10V RF Power Supply 2
h = Heat-Sink Temperature 1
i = Heat-Sink Temperature 2
j = Isolator Load Temperature
k = Shutdown
l = Fan 1
m = Fan 2
n = BUC
o = External Reference
CAS?
CAS=x….x
(see Description of
Arguments)
Summary of Contents for KPA series
Page 30: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Installation MN KPA IOM 2 4 Notes...
Page 84: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix A MN KPA IOM A 6 Notes...
Page 124: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix C MN KPA IOM C 30 Notes...
Page 126: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...