I N S T A L L I N G C O M S I F T E R
User Guide |
ComSifter CS-8D Pro
2–4
Audible Tones
Audible Tone
Frequency
Issue
Resolution
Slow Beep
One (1) beep every
three (3) seconds for
30 seconds—then no
beeps for 4½
minutes. Repeats
every five (5)
minutes.
Duplicate IP on the
WAN side of the
ComSifter
Internet Service Provide (ISP) has
duplicated the IP assigned to the account.
Condition may clear after a few minutes. If
it does not clear, it will be necessary to
contact the ISP.
Fast Beep
One (1) beep every
second for 30
seconds—then no
beeps for 4½
minutes. Repeats
every five (5)
minutes.
Duplicate IP on the
LAN side of the
ComSifter
More than one device is serving DHCP
information, or another device on the
network has been manually assigned the
same IP address as the ComSifter.
Constant Beep Continuous
Overheating condition
The ComSifter is not receiving proper air
circulation or the internal fan has stopped
working.
Short Beep
Twice/short
During the boot
sequence, or if a
network cable has
been removed and
reinserted
None