Troubleshooting (FAQ)
The table below reports the most common possible issues, with the related solutions.
ID
Problem
Actions
1
The system does not
switch ON
-
Check the presence of the main power supply voltage, within the
declared operating range
-
Check that power cable is connected to X1 plug of the controller
-
Check status of F1 fuse
-
Check that ON button has been pressed
2
The panels don’t move
-
Check that no obstacle/frictions are present and that the panels
movement is free
-
Check that all motor connections are present
-
Check main power supply presence
-
Check that door drive is powered and switched ON
-
Check the door movements in Inspection mode
-
Check RVC-DETC logic input P-21 P-31
3
The system switches ON,
but the door does not move
properly
-
Check the movements in Inspection mode:
o
if the door is moving in the opposite side
check P-22 settings
o
if the display shows an alarm code
refer to the alarms table
-
Check the speed profiles:
o
The door is moving with reduced speed
check if RSC input is
active and that P-99 is correctly set
o
The door does not move and the display shows an alarm code
refer to the alarms table
4
The system moves properly
in Inspection mode, but not
in Normal mode
-
Check if CDD6 is correctly set in Normal mode
-
Check the correct opening after DOC activation without RCS command
active
-
Check the correct closing after DCC activation without RCS command
active
-
Check correct settings of parameter P-99
5
The system does not react
to the activation of the
external reversing sources
-
Check that external reversing sources are correctly connected to the door
drive and that the wirings are correct
-
Check the reversing sources are correctly powered and switch according
the obstacle presence.
-
Check the correct settings for parameters P-04 P-21 P-31
6
The system does not
activate the closing force
detection
-
Check correct settings for closing force limit
-
Check correct settings of parameters P-00.
- Table 26: Trouble-shooting -
In the next paragraph are reported, in a more detailed way and as check-list, the main situations described
in the previous table, with the related checks and actions to be performed so to fix the possible issue.