Computec
CDD6
EN
CDD6: user manual – rev.07
Page 31/74
4.5
Door Learning function
The door learning function is the basic fundamental operation to be performed, to obtain a correct
behaviour of the system. The CDD6 controller can perform:
1.
Automatic learning
This procedure permits to learn automatically: the installed motor, the closing rotation, the
exact skate space measured on the belt (the skate type too), the door space, the closing and
opening torque profile at the normal speed profile. Please remember (before starting the
learning procedure or after its completion), to set all the other parameters that identify the
door operator (P-05 car door lock, P-99 MLC interface). The auto-set procedure allows an
optimal tuning of the controller interfaced to the door operator.
NOTE: please refer to chapter 5, for the parameter list and set-up
4.5.1
Auto-set procedure: automatic learning function
This feature allows to automatically learn:
1.
Installed motor type
2.
Closing rotation
3.
Actual skate space
4.
Door space
Execution:
STEP
Operation
Action
Result / Checks
1
Door drive
Power off
Switch off door drive by pressing OFF
key
Check the door drive is OFF
2
Door panels
positioning
Set manually the door position at
closed panels and skate opened (gap
between panels <10cm)
To optimize the execution of the
learning procedure, it is suggested but
not necessary to couple car and
landing door, executing the operations
from the car roof in inspection mode.
Check the correct panels closed position with
gap <10cm
3
AUTOSET start
Press and keep pressed key 1, and
press ON key. When autoset started,
release key 1.
Floor(s) with DTBC contact active (not
available for magnetic switches
applications):
AUTOSET for second TB
will start automatically.
Press ON button on the door drive front
panel, checking that “SL”
(“S2” for DTBC
contact floor) is shown on the door drive
display.
During all the auto-set steps, in case the of
errors or alarms, please refer to the NOTE at
the end of this table.
4
Motor check
Wait
The door moves shortly in both directions to
acquire information.
The CDD6 performs the motor check:
- connections
- motor type
- closing rotation