Computec
CDD6
EN
CDD6: user manual – rev.07
Page 39/74
N°
RANGE
UNIT
DEFAULT
Name
Values Description
OPENING PARAMETERS
A0
[1 ; 40]
mm
20
Door open search threshold offset
Offset for door open position (from P-A1)
A1
[2 ; 20]
mm
5
Door open parking threshold
Final space for door open parking position
A2
[0 ; 50]
mm
5
Acceleration start space
Offset respect to the panels closed
position
A3
[10; 50]
mm
20
Back-step space in case of reversing
during opening
Space of door re-closing when a reversing
source is detected during opening
A4
[10 ; 40]
cm/s
30
Skate speed
Speed for skate opening profile
A5
[2 ; 10]
cm/s
5
Low start speed
Speed for opening profile start
A6
[10;100]
cm/s
50
High speed
-
A7
[2; 10]
cm/s
3
Low final speed
-
A8
[8 ; 24]
cm/s
16
Reduced speed value
-
A9
[5 ; 25]
dm/s
2
10
Stop deceleration limit
-
AA
[1 ; 20]
dm/s
2
7
Profile deceleration limit
Only for magnet switches applications
AB
[1 ; 20]
dm/s
2
7
Acceleration limit
Only for magnet switches applications
AC
[2 ; 12]
A
9
Profile maximum current
-
AD
[2 ; 12]
A
9
Reset trip maximum current
-
AE
[25 ; 75]
%
35
Parking current
Percentage of nominal motor current
B4
[0 ; 4]
-
2
Default Opening profile
B5
[50 ; 80]
%
60
Profile symmetry
B7
[0 ; 99]
s
30
Timeout park with reduced current
B8
[0 ; 50]
mm
20
Unlocking space at power-off
BA
[0 ; 99]
%
90
Reverse force value
BB
[0 ; 1]
-
0
Opening reversing type
0=back-step, 1=no-torque
CLOSING PARAMETERS
C0
[1 ; 20]
mm
2
Door locked search threshold offset
Offset for door close position (from P-C1)
C1
[2 ; 10]
mm
3
Door locked parking threshold
Final space for door close parking position
C2
[0 ; 50]
mm
2
Deceleration end space
Offset respect to the panels closed
position
C3
[10 ; 50]
mm
20
Back-step space in case of reversing
during closing
Space of door re-opening when a
reversing source is detected during closing
C4
[10 ; 40]
cm/s
30
Skate speed
Speed for skate closing profile
C5
[2 ; 10]
cm/s
4
Low start speed
Speed for opening profile start
C6
[10 ; 50]
cm/s
35
High speed
-
C7
[2; 10]
cm/s
3
Low final speed
-
C8
[8; 24]
cm/s
16
Reduced speed value
-
C9
[5 ; 25]
dm/s
2
10
Stop deceleration limit
-
CA
[1 ; 20]
dm/s
2
4
Profile deceleration limit
Only for magnet switches applications
CB
[1 ; 20]
dm/s
2
4
Acceleration limit
Only for magnet switches applications
CC
[2 ; 12]
A
9
Profile maximum current
-
CD
[2 ; 12]
A
9
Reset trip maximum current
-
CE
[25 ; 75]
%
50
Parking current
Percentage of nominal motor current
D4
[0 ; 4]
-
2
Default Closing profile
D5
[40 ; 80]
%
60
Profile symmetry
D6
[0 ; 2]
-
2
Closing profile type
D7
[0 ; 99]
s
10
Timeout park with reduced current
D8
[-9
;
+20]
mm
5
Reverse disable offset from panels
closed position
Offset respect to the panels closed
position, to disable reversing
D9
[0 ; 1]
-
1
Closing force limit self-tuning
00=disabled
01=enabled
DA
[0 ; 99]
%
50
Set Force limit
DB
[8 ; 12]
N*10
11
MIN force limit
DC
[12 ; 30]
N*10
15
MAX force limit
- Table23: parameter list of the CDD6 door drive
–