5.9
Particular Parameters
5.9.1
P-43: Door open parking with no torque
This parameter permits to enable the opening parking without torque applied to the motor. The are some
field installations with landing manual swing doors, and car automatic sliding doors, the normally park at
the floor with the car door opened to permit the manual opening of the landing swing door.
This condition, similarly to the closed parking management, implies a continuous torque applied to the
motor. To avoid this, it is possible to enable this function.
Parameter value
Notes
00 = OP parking with
reduced torque NOT
ACTIVE
(
default value
)
The controller, during the OP parking phase, keeps always active the parking torques
to the motor.
01 = OP parking with
reduced torque ACTIVE
The controller activates the OP reduced torque parking function
5.9.2
P-85: Reset Speed value
This parameter allows to change the reduced speed value during power ON synchronization trip
Parameter
Range
Default value
Reduced speed
[50 ; 200 ] mm/s
100 mm/s
5.9.3
P-A8 / P-C8: Reduced Speed value
This parameter allows to change the reduced speed value during reduced speed trips (when RSC is active)
Parameter
Range
Default value
Reduced speed
[80 ; 240 ] mm/s
160 mm/s
NOTE: Reduced speed must not exceed the values shown below (4J kinetic Energy):
Panels weight [Kg]
Max Reduced speed
80
310 mm/s
100
280 mm/s
150
230 mm/s
200
200 mm/s
250
180 mm/s
300
160 mm/s
𝑹𝒆𝒅𝒖𝒄𝒆𝒅 𝑺𝒑𝒆𝒆𝒅 ≤ √𝟖/𝑾𝒆𝒊𝒈𝒉𝒕