4.6
Diagnostic Functions
4.6.1
Diagnostic operations by HMI
The diagnostic operations allowed by door drive front panel are limited, but permit to execute some basic
functions as described below.
- Figure 4-4: CDD6 front panel -
4.6.1.1
Profiles check in Inspection Mode
It is possible to verify the correct opening and closing of the door, activating the Inspection Mode from the
front panel (pressing key 4, until INSP LED is ON). In this mode it is possible to check:
-
Correct setting of the closing rotation (pressing key 2 or 3 and checking opening and closing
accordingly)
-
Correct execution of the normal speed profiles
-
Correct setting of the door opened and door closed, checking the feedback from the display that
shows “oP” and “CL” blinking and becomes fixed when movement is completed.
4.6.1.2
Alarm code reading and alarms reset in Normal Mode
It is possible to read the last warning/alarm code activated by the door drive keeping pressed the key “2”
on the drive front panel, when the drive is in Normal mode. While the alarm is visualized, press key “3” for
3 second to delete it.