Error messages 162
* Expansion Aborted due to Unrecoverable Drive Errors.
* Expansion Aborted due to Array Accelerator Errors.
Select "F1" to continue with logical drives disabled
Select "F2" to accept data loss and to re-enable logical drives
Audible Beeps
: None
Possible Cause
: Data was lost while the array was expanded; therefore, the drives have been temporarily
disabled. Capacity expansion failed due to:
•
Array accelerator or hard drive failed or was removed; expansion progress data lost
•
Expansion progress data could not be read from array accelerator
•
Expansion aborted due to unrecoverable drive errors
•
Expansion aborted due to array accelerator errors
Action
:
•
Press the
F1
key to continue with the logical drives disabled. Or, press the
F2
key to accept the data loss
and re-enable the logical drives.
•
Restore data from backup.
•
Replace drive or array accelerator, as appropriate.
1770-Slot X Drive Array - Disk Drive Firmware Update Recommended - ...
...Please upgrade firmware on the following drive model(s) using ROM Flash Components (download from
www.hp.com/support/proliantstorage): Model XYZ (minimum version = ####)
Audible Beeps
: None
Possible Cause
: Drive firmware update needed.
Action
: The indicated drives are running firmware that is known to cause intermittent problems. Update all
drives to the latest firmware version ("
Firmware maintenance
" on page
82
).
1771-Primary Disk port Address conflict
Audible Beeps
: None
Possible Cause
: Internal and external hard drive controllers are both assigned to the primary address.
Action
: Run the server setup utility and correct the configuration.
1772-Secondary Disk port Address conflict
Audible Beeps
: None
Possible Cause
: Address assignment conflict. Internal and external hard drive controllers are both assigned
to the secondary address.
Action
: Run the server setup utility and correct the configuration.