Error messages 150
Audible Beeps
: None
Possible Cause
: This configuration is not recommended because of controller memory requirements.
Action
: Perform RAID migration to lower stripe size using the Array Configuration Utility (on page
72
).
1712-Slot X Drive Array - RAID 5 logical drive(s) configured with 56 Drives, but Array
Accelerator size <= 32 MB...
...This configuration is not recommended. Consider migrating logical drive(s) to RAID 0 or 1, reducing the number of
drives in the array, or upgrading the Array Accelerator module.
Audible Beeps
: None
Possible Cause
: Upgrade the Array Accelerator module to a larger size.
Action
: Migrate logical drives to RAID 0 or 1, reduce the number of drives in the array, or upgrade to a
larger-size array accelerator module.
1713-Slot X Drive Array - Redundant ROM Reprogramming Failure...
...Replace the controller if this error persists after restarting system.
Audible Beeps
: None
Possible Cause
: Flash ROM is failing. The controller detects a checksum failure, but is unable to reprogram
the backup ROM.
Action
:
1.
Update the controller to the latest firmware version ("
Firmware maintenance
" on page
82
).
2.
If the problem persists, replace the controller.
1714-Slot X Drive Array - Redundant Checksum Error...
...Backup ROM has automatically been activated; check firmware version.
Audible Beeps
: None
Possible Cause
: The controller flash operation is interrupted by a power cycle, or flash ROM is failing. The
controller detects a ROM checksum error and automatically switches to the backup ROM image.
Action
: If this backup ROM image is a lower version than the originally running image, update the controller
to the latest firmware version.
1715-Slot X Drive Array Controller - Memory Error(s) Occurred...
...Warning: Corrected Memory Error(s) were detected during controller memory self-test. Please replace the controller
if this error persists.
Audible Beeps
: None
Possible Cause
: The memory is beginning to fail.
Action
: If this error persists, replace the controller.
1716-Slot X Drive Array - Unrecoverable Media Errors Detected on Drives during
previous Rebuild or Background Surface Analysis (ARM) scan...
...Errors will be fixed automatically when the sector(s) are overwritten. Backup and restore recommended.