Error messages 156
Audible Beeps
: None
Possible Cause
: A problem exists with the storage enclosure redundant cabling. A single path was found to
drives that were previously connected redundantly.
Action
:
Check the storage box I/O module and cable to restore redundant paths to the drives, then do one of the
following:
•
If the redundant cables/paths were not purposefully removed, press
F1
to display this message on
reboot until the problem is resolved. The drives should be accessible through the remaining path.
•
If the redundant paths were purposefully removed, press
F2
to disable this message on all subsequent
reboots.
1739-Slot X Drive Array - Redundant Cabling is not as recommended...
(followed by one or more of the following:)
...* Storage box has multiple paths from same controller port
* I/O modules are not cabled for good fault tolerance
* Redundant I/O paths exist due to direct loopback of controller ports
* Redundant I/O module supported and unsupported storage boxes are cabled together.
* Refer to product user guide
Audible Beeps
: None
Possible Cause
: Incorrect redundant cabling configuration
Action
: For information on how to cable the device in a supported manner for dual-domain redundant path
support, see the product user guide.
1740-Fixed Disk 0 failed Set Block Mode
Audible Beeps
: None
Possible Cause
: Fixed drive error detected.
Action
: Run the server setup utility and correct the configuration.
1741-Fixed Disk 1 failed Set Block Mode
Audible Beeps
: None
Possible Cause
: Fixed drive error detected.
Action
: Run the server setup utility and correct the configuration.
1743-Slot X Drive Array - Logical Drive Erase Operation in Progress...
...Logical drives being erased are temporarily offline.
Audible Beeps
: None
Possible Cause
: The drives being erased are offline.
Action
: Do one of the following:
•
Wait for the erase process to complete before using the logical drive.
•
Abort the erase process using ACU ("
Array Configuration Utility
" on page
72
).