Error messages 147
1615-Power Supply Configuration Error
Audible Beeps
: None
Possible Cause
: The server configuration requires an additional power supply. A moving bar is displayed,
indicating that the system is waiting for another power supply to be installed.
Action
: Install the additional power supply.
1615-Power Supply Configuration Error
- A working power supply must be installed in Bay 1 for proper cooling.
- System Halted!
Audible Beeps
: None
Possible Cause
: The server configuration requires an additional power supply. A moving bar is displayed,
indicating that the system is waiting for another power supply to be installed.
Action
: Install the additional power supply.
1615-Power Supply Failure, Power Supply Unplugged, or Power Supply Fan Failure
in Bay X
Audible Beeps
: None
Possible Cause
: The power supply has failed, or it is installed but not connected to the system board or AC
power source.
Action
: Reseat the power supply firmly and check the power cable or replace power supply.
1616-Power Supply Configuration Failure
-A working power supply must be installed in Bay 1 for proper cooling.
-System Halted!
Audible Beeps
: None
Possible Cause
: Power supply is improperly configured.
Action
: Run the server setup utility and correct the configuration.
1700 Series
1700-Slot X Drive Array - Please replace Array Accelerator Battery...
...The Array Accelerator Cache will be enabled once the battery has been replaced and charged.
Audible Beeps
: None
Possible Cause
: The battery needs to be replaced and charged.
Action
: Replace and charge the Array Accelerator battery.
1701-Slot X Drive Array - Please install Array Accelerator Battery...
...The Array Accelerator Cache will be enabled once the battery is installed and charged.