Error messages 126
Fatal Hub Link Error
Audible Beeps
: None
Possible Cause
: The hub link interface has experienced a critical failure that caused an NMI.
Action
: Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
77
) and replace failed components as
indicated.
FATAL ROM ERROR: The System ROM is not Properly Programmed.
Audible Beeps
: 1 long, 1 short
Possible Cause
: The System ROM is not properly programmed.
Action
: Replace the physical ROM part.
Fibre Channel Mezzanine/Balcony Not Supported.
Audible Beeps
: 2 short
Description
: The Fibre Channel adapter is not supported on the server.
Action:
Install the supported Fibre Channel adapter.
High Temperature Condition detected by Processor X
Audible Beeps
: None
Possible Cause
: Ambient temperature exceeds recommended levels, fan solution is insufficient, or fans have
failed.
Action
: Adjust the ambient temperature, install fans, or replace the failed fans.
Illegal Opcode - System Halted
Audible Beeps
: None
Possible Cause
: The server has entered the Illegal Operator Handler because of an unexpected event. This
error is often software-related and does not necessarily indicate a hardware issue.
Action
: Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
77
) and replace any failed components as
indicated. Be sure that all software is installed properly.
iLO Generated NMI
Audible Beeps
: None
Possible Cause
: The iLO controller generated an NMI.
Action
: Check the iLO logs for details of the event.