SRM Console Commands
7
-
57
7.5.33 Show Power
The show power command gives the power status of the system (AlphaServer
8400 system with H7263 power regulators installed).
Example 7-33 Show Power Command
>P00>>> show power
Cabinet: Main
Regulator :
A
B
C
----------------------------------------------------------------------
Primary Micro Firmware Rev :
2.0
2.0
2.0
Secondary Micro Firmware Rev :
2.0
2.0
2.0
Power Supply State :
NORMAL NORMAL NORMAL
AC Line Voltage (V RMS) :
113.71 114.35 115.93
DC Bulk Voltage (VDC) :
227.02 227.02 227.02
48V DC Bus Voltage (VDC) :
47.57 47.57 47.57
48V DC Bus Current (ADC) :
30.17 29.68 29.58
48V Battery Pack Voltage (VDC) :
50.85 50.72 47.91
24V Battery Pack Voltage (VDC) :
25.56 25.56 23.95
Battery Pack Charge Current (IDC) :
2.91
2.90
0
Ambient Temperature (Degree C) :
26.22 24.80 24.75
Elapsed Time (Hours) :
290.00 290.00 290.00
Remaining Battery Capacity (Minutes) :
8.00
8.00
8.00
Battery Cutoff Counter (Cycles) :
0
1.00
1.00
Battery Configuration : 4 Batteries 4 Batteries 4 Batteries
Heatsink Status :
NORMAL NORMAL NORMAL
Battery Pack Status :
CHARGING CHARGING DISCHG’G
Last UPS Test Status :
PASSED PASSED TESTING
The show power command syntax is:
sh[ow] p[ower] [-{h,s}] [option]
where -s displays the current status (default) and -h the history status (value of each
parameter at the last system shutdown) and option selects the cabinet (main, right, or
left).