Page 30
Ci Scanner Service Manual
6. Disconnect the USB
connection to the board to
allow the PCB Tray to
come off.
7. Disconnect the inline
connector of the mains
cable.
NOTE: These cables go through the
cover with suppressors, the wires are
hard soldered on, and can be easily
broken off, and so great care is needed
when handling this cable. A soldering
iron is required to change the
suppressors, so it is recommended the
PCB Tray is replaced should these
break in the field.
8. Pull out the PCB Tray and
lower enough to be able to
reach the mains connector
to the board without putting
strain on the cable.
Summary of Contents for SmartLF Ci 40
Page 12: ...Page 12 Ci Scanner Service Manual...
Page 40: ...Page 40 Ci Scanner Service Manual 13 Close the Lid Unit...
Page 45: ...Page 45 Ci Scanner Service Manual 7 Close the Lid Unit...
Page 96: ...Page 96 Ci Scanner Service Manual...
Page 97: ...Page 97 Ci Scanner Service Manual...
Page 98: ...Page 98 Ci Scanner Service Manual 17 4 MAIN BOARD...
Page 99: ...Page 99 Ci Scanner Service Manual...
Page 100: ...Page 100 Ci Scanner Service Manual...