29. Close the lid unit and rotate
the scanner to gain access to
the main board underneath
the scanner.
30. Using pliers, push the CIS
cables squarely back into the
appropriate connectors.
These cables are kept short
to maintain EMC compliance.
Care must be taken to ensure
the cables are not damaged
during insertion. Make sure
each cable is located
properly so that no silver is
showing.
31. Press the locking plate back
up to make contact and stop
the cable being pulled free
again.
32. Replace the PCB Tray as in
Chapter 11.4 'PCB Tray'.