Page 55
Ci Scanner Service Manual
12.6.
CIS PLATE ASSEMBLY
12.6.1 Safety Precautions
Ensure the power is completely disconnected from the scanner unit.
Ensure the scanner is positioned on a stable maintenance platform.
Follow chapter 10.3 to position the scanner in the maintenance position when required.
Employ static safety precautions when handling electronic boards and integrated circuits.
12.6.2 Tools
Small pozi-drive screwdriver
Medium pozi-drive screwdriver
Pliers
5.5mm Spanner
Thread lock
12.6.3 Associated Part Numbers
P003402 Ci40 CIS Plate Sub-A
P003401 Ci24 CIS Plate Sub-A
12.6.4 Procedures
1. Remove the PCB Tray as in
Chapter 11.4 'PCB Tray'
2. Do not remove the whole
Main Board, but only
release the 5x CIS ribbon
cables from the board as
described in Chapter 12.5.
3. Press down on the locking
buttons on both ends of the
lid unit.