Page 27
Ci Scanner Service Manual
9. Close the lid unit. If the Lid
Cover Extrusion Sub-A
does not line up with the
end cover, open the lid unit
again and adjust the
second set of screws to
raise the lid cover.
10. To raise the Lid Cover
Extrusion Sub-A, loosen
the 4 x holding screws (in
the elongated holes). Then
tighten the adjust screw
next to it to push the lid
further away from the lid
unit. Tighten the holding
screws again to lock the lid
cover in place.
11. To lower the lid cover,
loosen the adjustment
screws, and tighten the
holding screws.