11 | Repair
64 / 76
Operating instructions CMVpro 125-400 | Version 1-en
11.7
Electric motor exchange
Conditions:
• Fan has been prepared for repairs
_
60].
• Impeller has been removed
_
Procedure:
• Remove the motor connec-
tion cable from the terminal
box of the electric motor
and protect from damage.
• Support and secure the
electric motor with suitable
supports.
• Loosen mounting nuts on
motor flange.
• Move a heavy electric motor
with suitable hoisting gear.
• Use the lifting eye bolt
on the electric motor for
this purpose.
Fig. 38:
Removing the electric motor
Mounting instructions
NOTICE
Risk of damage to the electric motor
Damaged motor bearings.
u
Protect the motor shaft/bearings from impacts during transport and mount-
ing of the electric motor.
u
Observe the instructions in the manual from the motor manufacturer.
• Fasten mounting nuts according to the following table.
• The thread is based on the motor size.
Thread
Max. tightening torque
[Nm]
M8
22
M10
45
M12
80
M16
190
• Connect electric motor
_
• Check motor rotation direction
_
47].
• Conduct test run
_
48].