List of events
98-165591-B
Appendix B: System messages
B-4
BBBB
0807E-0
WARNING Keyline signal
The keyline signal on the dual antenna master does not
match the keyline signal on the slave. Check that the
keyline splitter cable is connected to the RS422
connectors. When fixed, the ACU's needs to be rebooted
to clear the event.
0807F-0
WARNING Local
administration
enabled
Local administration mode is currently enabled. This allows
login without providing the admin password. Will be
disabled after 1 hour or next reboot.
08080-0
WARNING Satellite info
mismatch
Currently selected manual satellite information does not
match information from the modem. Please select another
satellite for manual pointing.
08081-0
WARNING BUC
communication
Missing communication between VMU and BUC. Info:
0x00000001: From VMU to BUC Info: 0x00000002: From
BUC to VMU
08083-0
WARNING Friction test
timeout
Friction test timeout. Info code format: 0xaaaatttt, where
aaaa = axis under test (0=Azi, 1=XEL, 2=EL) and tttt =
timeout type. Info: 0xaaaa0001: Axis aaaa did not get
ready for test in time Info: 0xaaaa0002: Axis aaaa test did
not finish in time
08100-0
ERROR
PSM low voltage
(22 V)
The ADM measures a different antenna voltage than
expected. If the problem is not solved by a restart, and the
PSM is not reporting any errors, the ADM is probably
defective.
08101-0
ERROR
PSM high voltage
(48 V)
The ADM measures a different antenna voltage than
expected. Check for short circuit of the antenna coax
connector. If the problem is not solved by a restart, and the
PSM is not reporting any errors, the ADM is probably
defective.
08102-0
ERROR
PSM 5 V power
Internal voltage supply error of the ADM.
08103-0
ERROR
ADM hotswap
The ACU is not able to supply the correct voltage to the
antenna. Check for short circuits in coax cable and the
antenna
08104-0
ERROR
Antenna
communication
The ACU cannot communicate with the antenna. Check
cable and antenna.
08107-0
ERROR
ADM FPGA load
The ADM FPGA cannot be initialised and loaded.
08108-0
ERROR
TX Power
Detector
calibration
The power detector calibration is not valid.
Event ID
Severity
Description
Explanation