To assemble the EXPLORER 6075LX
98-165591-B
Chapter 3: Assembly & start up
3-9
3333
Important
If you are making your own power cable, you
must connect the Enable
signal (2-)
, otherwise you cannot switch on the EXPLORER 6075LX! You have
two options:
• Connect pin
2-
(Enable) to GND (pin
2+
). This means you can only switch
the EXPLORER 6075LX on and off using the Power switch on the Base Unit.
• Connect a
remote on/off switch
between pin
2-
(Enable) and pin
2+
(GND). This means that when the Power switch on the Base Unit is on, you
can use your own remote switch to turn the unit on and off.
Figure 3-14: DC power, cable connector pinout.
1+: 24-48 VDC
(Red wire)
2-: Enable
2+: GND
Black wire
1-: Not connected
Cable connector
view from back