Hub Manager Status Display
40
DECrepeater 90TS Installation and Configuration
Configuring the Module (Cont.)
[10] Downline Upgrade (Cont.)
After you initiate the DLU process, the screen displays the following message:
DLU process started!
CAUTION
!
If power is interrupted during Stage 3 of the DLU process,
the firmware image can become corrupted. Do not turn off
power to the unit or perform any action that can cause the
unit to lose power during Stage 3 of the DLU process.
NOTE:
Because of variances in network configurations (load
path and traffic levels), this initial stage of the DLU
process can take up to 10 minutes to complete.
If your module is installed into a DEChub 90 or as a standalone unit, go to the section
titled DLU Process Completion, on the following page.
If your module is installed into a DEChub 900, the screen displays the following
message:
Module not responding! Connection closed!
This is normal.
The Hub Manager status display indicates the following:
4:
DECrepeater 90TS
unknown
The Hub Manager status display continues to display this message until the DLU
process is complete. This is normal.