6
DECrepeater 90TS Installation and Configuration
Installing the Module (Cont.)
NOTE:
The module continually switches between the ThinWire
port and the AUI port if all of the following conditions are
true:
•
Both ports are unused
•
The ThinWire port is not terminated
•
The AUI port does not have a loopback
connector attached
This is not an error condition.
If you are connecting only the ThinWire port, and not the AUI port, go to Step 2.
1
Connect the AUI cable or MAU to
the AUI port :
a. Push the module’s AUI connec-
tor slide latch to the unlocked
position.
b. Insert the AUI cable plug or a
MAU into the AUI connector.
c. Push the module’s AUI connec-
tor slide latch to the locked posi-
tion.
d. If you are using only the AUI
port, and not the ThinWire port,
go to Step 3. Otherwise, go to
Step 2.
NOTE:
To disconnect the AUI cable or MAU, push the connector
slide latch to the unlocked position, then pull to
disconnect.
LKG-9476-94I
Unlocked
Back view