Diagnostics
The system’s microprocessor monitors and reports all active and violated zones when arming and
disarming. LED flashes indicate the active or violated zone; siren chirps indicate system status.
Arm/Disarm Diagnostics
The number of siren chirps will indicate the status of the alarm when arming and disarming. For
information on which zone is active or has been violated refer to the Table of Zones.
System Status Chirps
Table of Zones
NOTE: The Warn Away® response does not report on the LED.
Zone No.
Trigger type
Input description
1
Instant
H1/6 BLUE - Connect to optional hood/trunk pins.
2
On-board shock sensor
Heavy impact detected by the on-board shock
sensor.
3
Two-stage, progresses from
Door switch circuit. H1/5 GREEN or H1/7
VIOLET warning to full alarm
4
Multiplexed Input
BLUE and GREEN wires of optional sensor
plug. Inputs shorter than 0.8 seconds will trigger
a Warn Away response, while inputs longer than
0.8 seconds will instantly trigger a full alarm
sequence and report Zone 4.
5
Two-stage (similar to doors)
Ignition input. H1/9 YELLOW.
Action
Number of Chirps
Description
Arm
1
System armed
Arm
1 (3 second delay), 1
System armed with Bypass Notification
Disarm
2
System disarmed
Disarm
4
System disarmed with Tamper Alert
Disarm
5
System disarmed NPC® active
N426V_2008-08a.qxd 8/14/2008 10:31 AM Page 24
U
K
A
pproval Auth
or
it
y
24-Mar-10