TEST REPORT
Page 22 of 33
Issue Date: 2
nd
March 2010.
SGS Serial Number:
AUT130731/1/GH/10.
Test Report
Date: 01-13-2010
Time: 07:35:13
AUT: 130731/1.
Company Name :
Directed Electronics Inc.
Equipment Tested :
Viper Responder 350.
Serial Number :
691111266525.
Test Equipment used :
TESEQ Generators
Test Procedure Used :
ISO 7637 - 2.
General Conditions
Ambient Temperature :
18
Humidity :
47
Pressure :
987
Tested by :
G. Hann.
Signature :
Test Number 1
Test Name
12vp1.
Test Type
MT 5511 Pulse 1
Sequence Repetition
Count 5000
Test Status
PASS. B.
U
S
U
A
0
t
3
t
2
t
1
V
t
t
d
90%
10%
-
+
EU
T
Parameter
Operation
From
To
Step Size
Fail Value
Pulse Voltage (Us)
Static
75 V
---
---
---
Pulse Period (t1)
Static
0.5 s
---
---
---
General
Value
Rise Time (tr)
1 us
Output Resistance (Ri)
10 ohms
Pulse Width (td)
2 ms
t2
200 ms
Polarity/Coupling
Negative Parallel
Battery
Battery State
UPC/Time
Voltage 13.5
V
Current Limit
12.5 A
End of Test Voltage
13.5 V
Comments
During the test the Supply – flickered on/off, then returned to normal on completion of the test.
U
K
A
pproval Auth
or
it
y
24-Mar-10