© 2007 directed electronics
47
If the alarm exits adjustment mode automatically it will revert to its previous settings.
To lock in the new settings, you MUST exit using the
button after programming!
The total adjustment time for this sensor should be 5 minutes or less. Taking the time
to properly adjust this state-of-the-art sensor will give your customer years of unsur-
passed security and stop any returns for further adjustments.
1.
Disarm system
2.
Transmit Channel 16. (Press
3 times then
1 time)
z
The LED will turn on and the siren will chirp 1 time.
z
Primary (full trigger) zone adjustment has now been entered.
z
Primary zone can now be adjusted.
3.
Adjusting Primary Zone
z
Press
of the remote control to increase sensitivity.
z
Press
of the remote control to decrease sensitivity.
z
The sensor Primary zone can be tested at any time during adjustment and
will generate 1 siren chirp each time the zone is activated.
4.
Press
to adjust Warn-Away zone
z
Siren chirps 1 time.
z
Warn-away Zone adjustment has now been entered.
z
Warn-away Zone can now be adjusted.
5.
Adjust Warn-away Zone
z
Press
to increase sensitivity.
z
Press
to decrease sensitivity.
z
The sensor Warn-away zone can be tested at any time during adjustment
and will generate 1 siren chirp each time the zone is activated.
6.
Press
of the remote control to return to Primary zone adjustment and lock
in Warn Away zone setting.
z
Siren chirps 2 times
z
Primary zone can now be re-adjusted as described in step 3.
z
Or press
again to lock in primary zone setting and exit
programming mode.
z
The siren will chirp 3 times when sensor adjustment mode has been exited.
z
Auto-scroll for adjusting sensitivity
- press and hold
or
to
increase or decrease sensitivity setting several levels rapidly.
N919730P_01-07.qxd 1/12/07 3:41 PM Page 47
U
K
A
pproval Auth
or
it
y
24-Mar-10