Operator's Manual: Models CB-1500 & CB-2500 (230 V / 50 Hz)
3-13
Installing the Connector Block, Oil Line Tubing, and Air Line Tubing
(continued)
Installing the Oil Line Tubing (continued)
5.
Make sure that the curl in the oil line is positioned as shown in Figure 3G so that the burner can
swing open correctly.
6.
Install the oil line tubing and tighten the nuts on the compression fittings. DO NOT overtighten
these fittings to avoid damaging the ferrules.
NOTE:
You may also check the positioning of the oil line according to Figure 3H which provides a
larger front view of the connector block assembly.
Installing the Air Line Tubing
1.
Remove and discard the red caps from the air line tubing.
2.
Refer to Figure 3H. Push the air line tubing into the swivel fitting on the connector block until
the tubing bottoms out in the fitting.
3.
Repeat this procedure to connect the air line tubing to the air line fitting on the side of the burner.
220-240V 50-60Hz 3W
ts 10s
I88887
AIR OIL
OIL LINE FITTING
ON BURNER
AIR LINE FITTING
ON BURNER
OIL LINE
AIR LINE
COMPRESSION /
SWIVEL FITTING
CONNECTOR BLOCK
INSTALLED ON
FURNACE CABINET
Nr. 057H7036
Type BHO 64
Danfoss
Figure 3H - Installation of Connector Block, Oil Line and Air Line (Front View)
CB-1500 is shown
CB-2500 is similar
Summary of Contents for CB-500 series
Page 2: ......
Page 4: ......
Page 18: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz 1 10 ...
Page 60: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz 4 26 ...
Page 66: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz 5 6 ...
Page 74: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz 7 4 ...
Page 96: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz 10 8 ...
Page 114: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz A 18 ...
Page 122: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz D 2 ...