Operator's Manual: Models CB-1500 & CB-2500 (230 V / 50 Hz)
4-7
Raised Platform Mounting
WARNING:
To prevent serious personal
injury, make sure the platform is designed to
safely bear the weight of the furnace and allow safe
servicing of furnace components. The platform
must be constructed of non-combustible materials
(e.g. steel) and must be securely anchored to an
adjacent wall.
1.
Refer to Figure 4D, and follow the
instructions as provided in the diagram.
Floor Mounting
WARNING:
To prevent serious personal injury,
make sure the floor can safely bear the weight of
the furnace.
CAUTION:
If you are installing your furnace
in an area with a combustible floor, you must
construct a
non-combustible
floor as shown in
Figure 4E.
NOTE:
Make sure that blank cover panels are
installed over the bottom air discharge opening to allow
safe floor mounting.
1.
Refer to Figure 4E and follow the instructions
as provided in the diagram.
Figure 4E - CB-1500 Furnace Installed on Non-Combustible Floor (CB-2500 is similar)
Mounting the Furnace (continued)
Figure 4D - CB-1500 Furnace Installed on a
Raised Platform (CB-2500 is similar)
Danfo ss
Typ e BHO 6 4
Nr. 0 57 H7 036
ts 10 s
2 20 -2 4 0V 5 0- 60 Hz 3 W
AIR OIL
I88893
(1") LIP FOR
OIL CONTAINMENT
TALL CINDER BLOCK
MIN. 24 GA STEEL
2 PIECES FIREGUARD
COMBUSTIBLE MATERIAL
MIN. 5 cm (2") TALL MASONRY BLOCKS TO
ALLOW CLEARANCE FOR INSTALLATION OF
FITTINGS ON THE CONNECTOR BLOCK
PAN WITH MIN. 2.5 cm
MIN. 24 GA STEEL
20 cm (8") MIN.
I88894
1 PIECE
46 cm (18")
46 cm (18")
SHEETROCK OR EQUIVALENT
AIR OIL
N r. 057H 7036
Danfoss
Ty pe BH O 64
220-240V 50-60Hz 3W
ts 10s
Summary of Contents for CB-500 series
Page 2: ......
Page 4: ......
Page 18: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz 1 10 ...
Page 60: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz 4 26 ...
Page 66: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz 5 6 ...
Page 74: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz 7 4 ...
Page 96: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz 10 8 ...
Page 114: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz A 18 ...
Page 122: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz D 2 ...