Operator's Manual: Models CB-1500 & CB-2500 (230 V / 50 Hz)
3-11
Installing the Burner (continued)
Mounting the Burner on the Hinge Bracket
ATTENTION:
Burner tube components (e.g. electrodes and retention head) are factory set. Handle the
burner with extreme care so that burner components are not damaged.
1.
Remove the nut from the mounting flange of the furnace cabinet, and set it aside for later use.
2.
Lift the burner into position so that it is mounted on the hinge bracket on the furnace cabinet.
3.
Carefully swing the burner so the retention head enters the throat of the furnace.
4.
Check the clearance between the retention head and the furnace throat.
There must be at least
1/8" clearance, so the retention head is not "bumped" as you swing the burner into firing
position.
NOTE: If the retention head "bumps" the furnace throat, adjust the hinge bracket bolts
as follows:
•
While supporting the burner, slightly loosen the two (2) hinge bracket bolts.
•
Carefully re-position the burner so it swings freely into its firing position.
•
With the burner in its firing position, re-tighten the hinge bracket bolts.
Summary of Contents for CB-500 series
Page 2: ......
Page 4: ......
Page 18: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz 1 10 ...
Page 60: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz 4 26 ...
Page 66: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz 5 6 ...
Page 74: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz 7 4 ...
Page 96: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz 10 8 ...
Page 114: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz A 18 ...
Page 122: ...Operator s Manual Models CB 1500 CB 2500 230 V 50 Hz D 2 ...