Note: Clack Twin Alternator Operations
• Twin alternating systems can be programmed with a day override setting combined with the normal volume-based regeneration programming. 
A twin alternating system in this con

fi

 guration will then regenerate based on the volume used or the day override if there is a period of low water 

usage.
• Twin alternating systems can be programmed as a time clock only based regenerating system. In this con

fi

 guration, the days remaining are 

counted only on the unit that is in service. The unit in Stand-by Mode only notes days in diagnostics, which results in time clock only twin 
regeneration initiation.
• Twin alternating systems can be programmed for a delayed regeneration time. The system will allow an immediate transfer of the MAV to 
switch tanks and place a fully regenerated unit in service once a unit becomes exhausted. The exhausted unit will then be placed into Stand-by 
Mode and allowed to have a delayed regeneration at the pre-set time.

Retracted

Valve “A” in Service Position = 

MAV piston rod Retracted

Extended

Valve “B” in Service Position = 

MAV piston rod Extended

WS1, WS1.25 and WS1.5 Valves

For Clack Corporation alternator systems using WS1, WS1.25 and WS1.5 valves there will be an option to 
delay the last two cycles of regeneration (only “Rinse” and “Fill”). This feature splits the regeneration into 
two portions. The 

fi

 rst portion of the regeneration will start immediately and all programmed cycles before 

the “Rinse” and “Fill” cycles will be performed. After all programmed cycles before “Rinse” and “Fill” are 
completed the control valve will drive to the  service position (displaying “Delayed Rinse + Fill Pending”). 
When the volume of the on-line unit is depleted to 10% of its programmed capacity, the control valve will be 
triggered to 

fi

 nish the second portion of the regeneration and complete 

the “Rinse” and “Fill” cycles and return to Service and be placed into 
Standby mode, and wait to come on-line for service. Set to oFF to 
deactivate this feature.

WS2 Valve

For Clack Corporation alternator systems using the WS2 valve, when NEXT is pressed after selecting 
ALT A or ALT B, a display will allow the user to set the amount of pre-service rinse time for the stand 
by tank just prior to returning to service. With 1.0

 

 set, this display appears and is set in a similar 

manner. Set to oFF to deactivate this feature.

Summary of Contents for Water Specialist EI

Page 1: ...Water Specialist EI Control Valve Programming and Cover Drawing Manual...

Page 2: ...Page 2 EI Manual...

Page 3: ...EI Front Cover and Drive Assembly 4 Regeneration and Error Screens 5 User Displays 6 Configuration Settings 7 OEM Softener System Setup 11 Setting Options Table 14 OEM Filter System Setup 15 Installer...

Page 4: ...ront Cover and Drive Assembly AC Adapter U S International Supply Voltage 120V AC 230V AC Supply Frequency 60 Hz 50 Hz Output Voltage 15VDC 15VDC Output Current 500 mA 500 mA 1 Battery replacement is...

Page 5: ...user cannot cancel this request except by resetting the control by pressing NEXT and REGEN simultaneously for 3 seconds Regeneration Cycles and Times Button Operation and Function Changes variable bei...

Page 6: ...turn to the User Displays Time of day should only need to be set after power outages lasting more than 8 hours if the battery has been depleted and a power outage occurs or when daylight saving time b...

Page 7: ...ignal or one dP switch cannot be used for both controls on0 If the dP switch is closed for an accumulative time of 2 minutes a regeneration will be signaled to the unit In a twin alternating system th...

Page 8: ...peration For separate source operation the three wire communication cable is not used Selection requires that a connection to a Clack Motorized Alternator Valve MAV is made to the two pin connector la...

Page 9: ...rvice Position MAV piston rod Extended WS1 WS1 25 and WS1 5 Valves For Clack Corporation alternator systems using WS1 WS1 25 and WS1 5 valves there will be an option to delay the last two cycles of re...

Page 10: ...o Hard Water Bypass V3097 BSPT or V3098 BSPT to the two pin connector labeled MAV located on the printed circuit board is required Press NEXT to go to Step 6CS Press REGEN to return to previous step S...

Page 11: ...he brine tank after the final rinse or PrE to refill the brine tank four hours before the regeneration time set This screen is not viewed when Step 2S is set to Filtering Press NEXT to go to Step 5S P...

Page 12: ...matically calculated and reserve capacity will be automatically estimated oFF regeneration will be triggered solely by the day override setting see Installer Display Settings Step 4I a volume regenera...

Page 13: ...e meter Ranges from 1 to 200 liters Press NEXT to go to Step 15S Press REGEN to return to previous step Step 15S Set Relay Deactivate Time using or If Set Time on is selected in Step 13S the relay wil...

Page 14: ...be allowed to be set because regeneration will always occur when volume capacity reaches 0 Any number on 0 oFF Reserve capacity NOT automatically estimated Regeneration occurs immediately when volume...

Page 15: ...M3 See Setting Options Table for more detail Press NEXT to go to Step 6F Press REGEN to return to previous step Step 5F Step 6F Set Regeneration Time Options using or If value is set to NORMAL means r...

Page 16: ...from 1 second to 20 minutes Press NEXT to exit OEM Filter System Setup Press REGEN to return to previous step Step 9F EXIT OEM FILTER SYSTEM SETUP Step 7F Set Relay Operation using or The choices are...

Page 17: ...ximum number of days between regenerations If value set to oFF regeneration initiation is triggered solely by volume used If value is set in days allowable range from 1 to 28 regeneration initiation w...

Page 18: ...shows the total number of regenerations that have occurred since startup Press the NEXT button to go to Step 6D Press REGEN to return to previous step Step 5D Step 6D Error Log This display shows a hi...

Page 19: ...f A then the tank with the valve on it was in service if b the tank with the in out head on it was in service The next three digits represent the number of hours ago that the transfer occurred The dis...

Page 20: ...Page 20 EI Manual...

Page 21: ...EI Manual Page 21...

Page 22: ...Page 22 EI Manual...

Page 23: ...History 3 12 2015 PAGE 12 Step 13S Clarified relay operation PAGE 16 Step 7F Clarified relay operation 11 16 2016 PAGE 17 Step 3I updated text PAGE 4 Updates to table and drawing Bracket and Spring C...

Page 24: ...Page 24 EI Manual Form No V3435EI 8 24 2017 U S Patents 6 402 944 6 444 127 6 776 901...

Reviews: