OEM Softener System Setup
Step 1S -
Press NEXT and
▼
simultaneously for 5 seconds and release. If screen in Step 2S does not
appear, the lock on valve programming has been activated. To unlock press
▼
, NEXT,
▲
,
REGEN in
sequence, then press NEXT and
▼
simultaneously for 5 seconds and release.
Step 2S –
Choose SOFTENING using
▲
or
▼
. Press NEXT to go to Step 3S. Press REGEN to exit OEM
Softener System Setup.
Step 2S
Step 1S
Step 3S –
Choose Brining Direction using
▲
or
▼
. This screen is not viewed when Step 2S is set to
Filtering. Press NEXT to go to Step 4S. Press REGEN to return to previous step.
Step 3S
Step 4S –
Set Re
fi
ll location using
▲
or
▼
:
• “PoST” to re
fi
ll the brine tank after the
fi
nal rinse; or
• “PrE” to re
fi
ll the brine tank four hours before the regeneration time set.
This screen is not viewed when Step 2S is set to Filtering.
Press NEXT to go to Step 5S. Press REGEN to return to previous step.
Step 4S
Step 5S –
Select the time for the
fi
rst cycle using
▲
or
▼
.
Press NEXT to go to Step 6S. Press REGEN to return to previous step.
Step 5S
Step 6S –
Select the time for the second cycle using
▲
or
▼
.
NOTE: The display will
fl
ash between cycle number and time, and brine direction (UP or dn).
Press NEXT to go to Step 7S. Press REGEN to return to previous step.
Step 6S
Step 7S –
Select the time for the third cycle using
▲
or
▼
.
Press NEXT to go to Step 8S. Press REGEN to return to previous step.
Step 7S
Step 8S –
Select the time for the fourth cycle using
▲
or
▼
.
Press NEXT to go to Step 9S. Press REGEN to return to previous step.
Step 8S
Summary of Contents for Water Specialist EI
Page 1: ...Water Specialist EI Control Valve Programming and Cover Drawing Manual...
Page 2: ...Page 2 EI Manual...
Page 20: ...Page 20 EI Manual...
Page 21: ...EI Manual Page 21...
Page 22: ...Page 22 EI Manual...
Page 24: ...Page 24 EI Manual Form No V3435EI 8 24 2017 U S Patents 6 402 944 6 444 127 6 776 901...