Installer Display Settings
Step 1I -
To enter Installer Display press NEXT and
▲
simultaneously for about 5 seconds and release.
Step 1I
Step 2I –
Hardness: Set the amount of in
fl
uent hardness using
▲
or
▼
. This display will not be viewed if
FILTERING BACKWASH or FILTERING REGEN is selected in Step 2F OR if “oFF” or a number was
selected in Step 11S.
Press NEXT to go to step 3I. Press REGEN to exit Installer Display Settings.
Step 2I
Step 3I –
Service Water Hardness - If a mixing valve is installed in the valve, service hardness needs to be
set. Setting range is always less than the setting in Step 2I. This screen will not be displayed when valve is
set as a Filter, or if Auto is not selected in Step 11S.
Press NEXT to go to Step 4I. Press REGEN to return to previous step.
Step 3I
Step 4I –
Day Override: When volume capacity is set to “oFF”, sets the number of days between
regenerations. When volume capacity is set to AUTO or to a volume, sets the maximum number of days
between regenerations. If value set to “oFF”, regeneration initiation is triggered solely by volume used.
If value is set in days (allowable range from 1 to 28) regeneration initiation will be called for on that day
regardless of actual water usage. Set Day Override using
▲
or
▼
:
• number of days between regeneration (1 to 28); or
• “oFF”.
See Setting Options Table for more detail on setup.
Press NEXT to go to step 5I. Press REGEN to return to previous step.
Step 4I
Step 5I –
Next Regeneration Time (hour): Set the hour of day for regeneration using
▲
or
▼
. The default
time is 2:00. This display will show “REGEN on 0 M
3
” if “on 0” is selected in Set Regeneration Time
Option in OEM Softener System Setup or OEM Filter System Setup.
Press NEXT to go to step 6I. Press REGEN to return to previous step.
Step 5I
Step 6I –
Next Regeneration Time (minutes): Set the minutes of day for regeneration using
▲
or
▼
. This
display will not be shown if “on 0” is selected in Set Regeneration Time Option in OEM Softener System
Setup or OEM Filter System Setup.
Press NEXT to exit Installer Display Settings. Press REGEN to return to previous step.
Step 6I
EXIT INSTALLER DISPLAY SETTINGS
Summary of Contents for Water Specialist EI
Page 1: ...Water Specialist EI Control Valve Programming and Cover Drawing Manual...
Page 2: ...Page 2 EI Manual...
Page 20: ...Page 20 EI Manual...
Page 21: ...EI Manual Page 21...
Page 22: ...Page 22 EI Manual...
Page 24: ...Page 24 EI Manual Form No V3435EI 8 24 2017 U S Patents 6 402 944 6 444 127 6 776 901...