background image

Page 4

 

   EI 

Man 

u al

Drawing No.

Order No.

Description

Quantity

1

V3175EE-01

WS1EE FRONT COVER ASSEMBLY

1

2

V3107-01

WS1 MOTOR

1

3

V3002-A

WS1 DRIVE BRACKET ASY

1

4

V3408EI-04BOARD

WS1THRU2 EI PCBRD 5 DIGIT REPL

1

5

V3110

WS1 DRIVE REDUCING GEAR 12X36

3

6

V3109

WS1 DRIVE GEAR COVER

1

7

V3106-01

WS1 DRIVE BRACKET & SPRING CLIP

1

Not Shown

V3186-05

WS1 POWER SUPPLY US 15VDC VI

1

V3186EU-05

WS1 POWER SUPPLY EU 15VDC VI

V3186UK-05

WS1 POWER SUPPLY UK 15VDC VI

V3186-01

WS1 AC ADAPTER CORD ONLY

Not Shown

V3178

WS1 DRIVE BACK PLATE

1

EI Front Cover and Drive Assembly

AC Adapter

U.S.

International

Supply Voltage

120V AC

230V AC

Supply Frequency

60 Hz

50 Hz

Output Voltage

15VDC

15VDC

Output Current

500 mA

500 mA

1

Battery replacement is 3 volt 

lithium coin cell type 2032.

Correct 

Battery 

Orientation

Battery Fully Seated

When replacing the battery, align 

positives and push down to fully seat.

Refer to Control Valve Service Manual for other drawings and part numbers.

2

Relay Speci

fi

 cations: 12V DC Relay with a coil resistance not 

less than 80 ohms. If mounting relay under the cover check for 

proper mounting dimensions on the backplate.

Wiring for Correct On/Off Operation

PC Board Relay Terminal Block

Relay

RLY 1

Coil -

+ COM

Coil +

PC Board Relay 

Terminal Block

4

5

6

7

3

Summary of Contents for Water Specialist EI

Page 1: ...Water Specialist EI Control Valve Programming and Cover Drawing Manual...

Page 2: ...Page 2 EI Manual...

Page 3: ...EI Front Cover and Drive Assembly 4 Regeneration and Error Screens 5 User Displays 6 Configuration Settings 7 OEM Softener System Setup 11 Setting Options Table 14 OEM Filter System Setup 15 Installer...

Page 4: ...ront Cover and Drive Assembly AC Adapter U S International Supply Voltage 120V AC 230V AC Supply Frequency 60 Hz 50 Hz Output Voltage 15VDC 15VDC Output Current 500 mA 500 mA 1 Battery replacement is...

Page 5: ...user cannot cancel this request except by resetting the control by pressing NEXT and REGEN simultaneously for 3 seconds Regeneration Cycles and Times Button Operation and Function Changes variable bei...

Page 6: ...turn to the User Displays Time of day should only need to be set after power outages lasting more than 8 hours if the battery has been depleted and a power outage occurs or when daylight saving time b...

Page 7: ...ignal or one dP switch cannot be used for both controls on0 If the dP switch is closed for an accumulative time of 2 minutes a regeneration will be signaled to the unit In a twin alternating system th...

Page 8: ...peration For separate source operation the three wire communication cable is not used Selection requires that a connection to a Clack Motorized Alternator Valve MAV is made to the two pin connector la...

Page 9: ...rvice Position MAV piston rod Extended WS1 WS1 25 and WS1 5 Valves For Clack Corporation alternator systems using WS1 WS1 25 and WS1 5 valves there will be an option to delay the last two cycles of re...

Page 10: ...o Hard Water Bypass V3097 BSPT or V3098 BSPT to the two pin connector labeled MAV located on the printed circuit board is required Press NEXT to go to Step 6CS Press REGEN to return to previous step S...

Page 11: ...he brine tank after the final rinse or PrE to refill the brine tank four hours before the regeneration time set This screen is not viewed when Step 2S is set to Filtering Press NEXT to go to Step 5S P...

Page 12: ...matically calculated and reserve capacity will be automatically estimated oFF regeneration will be triggered solely by the day override setting see Installer Display Settings Step 4I a volume regenera...

Page 13: ...e meter Ranges from 1 to 200 liters Press NEXT to go to Step 15S Press REGEN to return to previous step Step 15S Set Relay Deactivate Time using or If Set Time on is selected in Step 13S the relay wil...

Page 14: ...be allowed to be set because regeneration will always occur when volume capacity reaches 0 Any number on 0 oFF Reserve capacity NOT automatically estimated Regeneration occurs immediately when volume...

Page 15: ...M3 See Setting Options Table for more detail Press NEXT to go to Step 6F Press REGEN to return to previous step Step 5F Step 6F Set Regeneration Time Options using or If value is set to NORMAL means r...

Page 16: ...from 1 second to 20 minutes Press NEXT to exit OEM Filter System Setup Press REGEN to return to previous step Step 9F EXIT OEM FILTER SYSTEM SETUP Step 7F Set Relay Operation using or The choices are...

Page 17: ...ximum number of days between regenerations If value set to oFF regeneration initiation is triggered solely by volume used If value is set in days allowable range from 1 to 28 regeneration initiation w...

Page 18: ...shows the total number of regenerations that have occurred since startup Press the NEXT button to go to Step 6D Press REGEN to return to previous step Step 5D Step 6D Error Log This display shows a hi...

Page 19: ...f A then the tank with the valve on it was in service if b the tank with the in out head on it was in service The next three digits represent the number of hours ago that the transfer occurred The dis...

Page 20: ...Page 20 EI Manual...

Page 21: ...EI Manual Page 21...

Page 22: ...Page 22 EI Manual...

Page 23: ...History 3 12 2015 PAGE 12 Step 13S Clarified relay operation PAGE 16 Step 7F Clarified relay operation 11 16 2016 PAGE 17 Step 3I updated text PAGE 4 Updates to table and drawing Bracket and Spring C...

Page 24: ...Page 24 EI Manual Form No V3435EI 8 24 2017 U S Patents 6 402 944 6 444 127 6 776 901...

Reviews: