EI Man u al
Page 15
OEM Filter System Setup
Step 1F -
Press NEXT and
▼
simultaneously for 5 seconds and release. If screen in Step 2CS does not
appear, the lock on the valve is activated. To unlock press
▼
, NEXT,
▲
,
REGEN
in sequence, then press
NEXT and
▼
simultaneously for 5 seconds and release.
Step 1F
Step 2F –
Choose FILTERING BACKWASH or FILTERING REGEN (see table) using
▲
or
▼
. Press
NEXT to go to Step 3F. Press REGEN to exit OEM Filter System Setup.
Step 2F
Step 3F –
Select the time for the
fi
rst cycle using
▲
or
▼
.
Press NEXT to go to Step 4F. Press REGEN to return to previous step.
Step 3F
Step 4F –
Select the time for the second cycle using
▲
or
▼
.
If Step 2F is set to FILTERING REGEN, press NEXT to program the rest of the cycle times. If Step 2F is
set to FILTERING BACKWASH, press NEXT to go to Step 5F. Press REGEN to return to previous step.
Step 4F
Step 5F –
Set Regeneration trigger using
▲
or
▼
. If value is set to:
• “oFF” regeneration will be triggered solely by the day override setting (see Installer Display/Settings Step
4I);
• a volume, regeneration will be triggered by the value speci
fi
ed (in M
3
).
See Setting Options Table for more detail.
Press NEXT to go to Step 6F. Press REGEN to return to previous step.
Step 5F
Step 6F –
Set Regeneration Time Options using
▲
or
▼
. If value is set to:
• “NORMAL” means regeneration will occur at the preset time;
• “on 0” means regeneration will occur immediately when the volume capacity reaches 0 (zero); or
• “ on 0” means regeneration will occur at one of the following:
— the preset time when the volume capacity falls below the reserve or the speci
fi
ed number of days
between regenerations is reached whichever comes
fi
rst; or
— immediately after 10 minutes of no water usage when the volume capacity reaches 0 (zero).
“NORMAL” is the default if Step 5CS is set to ALT A or ALT B, and “ on 0” is not
available.
“on 0” is the default if Step 2CS is set to 1.0
, and “ on 0” is not available.
This step will not appear if Step 5F is set to off or Step 5CS is set to “SYS”.
See Setting Options Table for more detail. Press NEXT to go to Step 7F. Press REGEN to return to
previous step.
Step 6F
Cycle Sequence, Adjustable Default Times (minutes)
Type
Backwash
Draw
Backwash
Rinse
Backwash*
Fill
Filtering Backwash
8
4
Filtering Regen
8
60
8
8
0:30
4.2 L
Filtering Regen (2.0”)
8
60
8
8
0:30
6
*Cycle is non-adjustable, not shown in cycle sequence programming.
Summary of Contents for Water Specialist EI
Page 1: ...Water Specialist EI Control Valve Programming and Cover Drawing Manual...
Page 2: ...Page 2 EI Manual...
Page 20: ...Page 20 EI Manual...
Page 21: ...EI Manual Page 21...
Page 22: ...Page 22 EI Manual...
Page 24: ...Page 24 EI Manual Form No V3435EI 8 24 2017 U S Patents 6 402 944 6 444 127 6 776 901...