C-4
Cisco UCS C210 Server Installation and Service Guide
OL-20887-02
Appendix
In some cases, the default extender backplane requires different cables than the optional expander
backplane. The cable connections required for each type of controller are as follows:
•
Integrated ICH10R:
–
Extender: Connect one SATA cable from the motherboard connector to the drives 1–4 connector
on the extender.
–
Expander: This integrated controller cannot be used with the expander.
•
1064E mezzanine card:
–
Extender: Connect one long SAS cable from the single connector on the mezzanine card to the
drives 1–4 connector on the extender.
–
Expander: Connect one short SAS cable from the single connector on the mezzanine card to
connector 1 on the expander.
•
LSI MegaRAID 9280-4i4e card:
–
Extender: Connect one short SAS cable from connector 1 on the card to the drives 1–4
connectors on the extender.
–
Expander: Connect one short SAS cable from connector 1 on the card to connector 1 on the
expander.
•
LSI MegaRAID 9261-8i card:
–
Extender: Connect one long SAS cable from connector 1 on the card to the drives 1–4 connector
on the extender. Connect one long SAS cable from connector 2 on the card to the drives 5–8
connector on the extender.
–
Expander: Connect one short SAS cable from connector 1 on the card to connector 1 on the
expander. Connect one short SAS cable from connector 2 on the card to connector 2 on the
expander. (Connector 1 on the expander can control up to 16 drives, connector 2 provides
redundancy.)
How to Determine Which Controller Is in Your Server
If you do not have a record of which device is used in the server, you can disable quiet boot and read the
on-screen messages that are displayed during system bootup. These messages display information about
the devices that are installed in your server.
•
Information about the models of card installed are displayed as part of the verbose boot. You are
also prompted to press
Ctrl-H
to launch configuration utilities for those cards. For servers running
CIMC firmware earlier than release 1.2(1), see also
How to Disable Quiet Boot for CIMC Firmware
Earlier Than Release 1.2(1), page C-5
.
•
If the mezzanine-style card is enabled, you are prompted to press
Ctrl-C
to launch the configuration
for these cards. See also
Enabling the Mezzanine Card RAID Controller in the BIOS, page C-3
.
•
If no models of card are displayed but there is a RAID configuration, your server is using the
onboard ICH10R controller. You are also prompted to press
Ctrl-M
to launch the configuration
utilities for this controller (see graphic below). See also
Enabling the Integrated Intel ICH10R RAID
Controller in the BIOS, page C-2
.
Summary of Contents for UCS C210
Page 12: ...xii Cisco UCS C210 Server Installation and Service Guide OL 20887 02 ...
Page 14: ...xiv Cisco UCS C210 Server Installation and Service Guide OL 20887 02 ...
Page 38: ...2 20 Cisco UCS C210 Server Installation and Service Guide OL 20887 02 Chapter ...
Page 92: ...B 8 Cisco UCS C210 Server Installation and Service Guide OL 20887 02 Appendix ...
Page 100: ...C 8 Cisco UCS C210 Server Installation and Service Guide OL 20887 02 Appendix ...