Module Commands
78-4025693-01 Rev D
41
MODID NAME VALUE UNITS
20/05 OutPwr 8.29224 dBm
20/06 InPwr 5.91542 dBm
20/06 OutPwr 18.9929 dBm
20/13 InPwr 17.2202 dBm
20/13 OutPwr 19.4671 dBm
SUCCESS!
*/* MODULE>
Note:
The information returned by the monitor argument includes units of
measurement.
InPwr values are stated to several decimal places, but only the first 2 or 3 are
significant.
Show Alarmstate
The following sample dialog shows the kind of information returned by the
alarmstate
argument.
*/* MODULE> show alarmstate *pwr <Enter>
MODID NAME STATE
20/05 OutPwr 0 (major low)
20/06 InPwr 0 (major low)
20/06 MaxInPwr 0 (ok)
20/07 OutPwr 2 (ok)
20/08 XSPwr 0 (ok)
20/13 OutPwr 0 (major low)
20/13 InPwr 0 (major low)
SUCCESS!
*/* MODULE>
Note:
The information returned by the
alarmstate
argument provides both the
numeric value and its meaning.
Show Alarmparam
Alarms also have parameters, such as thresholds. Accordingly, the
alarmparam
argument is in turn followed by an argument that specifies one of five parameters:
hysteresis
,
majorhigh
,
majorlow
,
minorhigh
, and
minorlow
.