Chapter 4 Operation Using ICIM
82
78-4025693-01 Rev D
CONFIG Menus
When the
CONFIG
menu is selected, the
Shelf
number field is highlighted. The
shelf and slot number fields may only be incremented with the
key or the
key. The
key highlights the
Slot
number field. Once you exit the slot field, the
Up and Down arrows will scroll through the parameters that are specific to this
module.
Sample
CONFIG
menus are shown below.
Note:
For details on all configurable parameters, see
Module Parameter Descriptions
(on page 143).
Hybrid Amplifier Service Mode
Service mode allows the user to reduce the output power of the module to 15 dBm
so that the optical cable connections can be made without the risk of damaging the
optical components.
The Hybrid Amplifier has multiple optical outputs that are divided into two banks.
You can change the Service mode status on all banks of optical outputs using the
Service control.
It is critical that optical connections be modified only when the module is in Service
mode. The optical output power of the module in the normal operating mode can
damage the optical components if cable connections are altered.
Summary of Contents for Prisma II
Page 1: ...78 4025693 01 Rev D Prisma II Hybrid Amplifier Installation Guide ...
Page 2: ......
Page 10: ......
Page 20: ......
Page 26: ......
Page 54: ......
Page 56: ...Chapter 3 Operation Using CLI 30 78 4025693 01 Rev D Prisma II Platform Configuration ...
Page 150: ......
Page 156: ......
Page 164: ...Appendix A Prisma II Permitted CLI Commands 138 78 4025693 01 Rev D Reserved for future use ...
Page 174: ......
Page 180: ......