Chapter 3 Operation Using CLI
40
78-4025693-01 Rev D
Alarm Module
The argument
module
can be added to modify the scope of the command to include
only the active alarms in the range indicated by the current Module prompt.
The following sample dialog shows how this argument affects the response.
20/* MODULE> alarm module <Enter>
No active alarms found
SUCCESS!
20/* MODULE>
This response indicates that no alarms are currently among the modules installed in
chassis 20. Alarms that may exist in other chassis are not reflected.
Show Command
The
show
command (at the Module prompt) is used to display the values of
parameters specified by one of four following arguments:
control
,
monitor
,
alarmstate
, or
alarmparam
. These arguments, in turn, are followed by the name of a
control (or monitor or alarm) to match against. This name can be the complete name
or a pattern that includes one or more wildcard characters (*).
Show Control
The following sample dialogs using the
control
argument show the use of both
complete names and wildcards, as well as the kinds of information returned.
*/* MODULE> show control enable <Enter>
MODID NAME SETTING UNITS
20/05 Enable On (1)
20/06 Enable On (1)
20/07 Enable On (1)
20/09 Enable On (1)
20/13 Enable Off (0)
SUCCESS!
*/* MODULE>
*/* MODULE> show control *serv* <Enter>
MODID NAME SETTING UNITS
01/07 Service Off (0)
01/08 ServiceA Off (0)
01/08 ServiceB On (1)
SUCCESS!
*/* MODULE>
Show Monitor
The sample dialog below shows the kind of information returned by the
monitor
argument.
*/* MODULE> show monitor *pwr <Enter>
Summary of Contents for Prisma II
Page 1: ...78 4025693 01 Rev D Prisma II Hybrid Amplifier Installation Guide ...
Page 2: ......
Page 10: ......
Page 20: ......
Page 26: ......
Page 54: ......
Page 56: ...Chapter 3 Operation Using CLI 30 78 4025693 01 Rev D Prisma II Platform Configuration ...
Page 150: ......
Page 156: ......
Page 164: ...Appendix A Prisma II Permitted CLI Commands 138 78 4025693 01 Rev D Reserved for future use ...
Page 174: ......
Page 180: ......