Module Commands
78-4025693-01 Rev D
47
This response shows that the OutPwr, LasTemp, LasBias, and InPwr alarms all have
majorlow and majorhigh parameters. However, only InPwr, OutPwr, and LasBias
can be changed, as LasTemp is of type 3 rather than 1, 2, or 7.
The following sample dialog shows how a craft operator would set the
majorhigh
parameter of
outpwr
to 35°C, and then confirm the change.
20/06 MODULE> set alarmparam outpwr majorhigh 35 <Enter>
SUCCESS!
20/06 MODULE>
20/06 MODULE> info alarm * type majorhigh
MODID NAME TYPE MAJORHIGH
20/06 PsOk 6 N/A
20/06 OutPwr 1 35
20/06 IntPs 6 N/A
20/06 Enable 6 N/A
20/06 LasTemp 3 15
20/06 LasBias 1 -0.01
20/06 InPwr 1 25
20/06 Service 5 N/A
SUCCESS!
20/06 MODULE>