4-12
PA-MC-T3-EC Port Adapter Installation and Configuration
OL-10589-02
Chapter 4 Configuring the Unchannelized Mode
Configuring an Unchannelized T3 Link
Sending a BER Test Pattern on the T3 Line
You can send a BERT pattern on the T3 line with the
bert pattern
pattern
interval
time
command in
controller configuration mode where:
•
pattern
is one of the following:
–
0s, repetitive test pattern of all zeros (as 00000...)
–
1s, repetitive test pattern of all ones (as 11111...)
–
2^15, pseudorandom O.151 test pattern (32,768 bits long)
–
2^20, pseudorandom O.151 non-QRSS test pattern (1,048,575 bits long)
–
2^23, pseudorandom O.151 test pattern (8,388,607 bits long)
–
alt-0-1, repetitive alternating test pattern of zeros (0s) and ones (1s) (as 01010101)
•
time
is 1 to 14400 minutes.
Examples follow:
•
Send a BERT pseudorandom pattern of 2^23 for 5 minutes.
The example that follows is for a port adapter in slot 1 of a Cisco 7200 VXR router:
Router(config)#
controller T3 1/0
Router(config-controller)#
bert pattern 2^23 interval 5
•
Send a repetitive pattern of all ones for 14400 minutes (240 hours).
The example that follows is for a port adapter in slot 1 of a Cisco 7200 VXR router:
Router(config)#
controller T3 1/0
Router(config-controller)#
bert pattern 1s interval 14400
Note
You can terminate a BER test during the specified test period with the
no bert
command.
Viewing the Results of a BER Test
You can view the results of a BER test using the
show controllers T3
slot/t3-port
controller command.
You can view the results of a BER test at the following times:
•
After you terminate the test using the
no bert
command
•
After the test runs completely
•
Anytime during the test (in real time)
The example that follows is for a port adapter in slot 5 of a Cisco 7200 VXR router:
Router#
show controllers T3 5/0
T3 5/0 is up. Hardware is 2CT3+ single wide port adapter
CT3 H/W Version : 0.1.1, CT3 ROM Version : 0.95, CT3 F/W Version : 1.4.4
FREEDM version: 1, reset 0
Applique type is Subrate T3
No alarms detected.
MDL transmission is disabled
FEAC code received: No code is being received
Framing is C-BIT Parity, Line Code is B3ZS, Clock Source is Internal
Rx throttle total 0, equipment customer loopback
Data in current interval (63 seconds elapsed):