3-9
PA-MC-T3-EC Port Adapter Installation and Configuration
OL-10589-02
Chapter 3 Removing and Installing Port Adapters
Cables and Connectors
Figure 3-6
Attaching 75-Ohm, 734A Coaxial Cables to a PA-MC-2T3-EC Port Adapter
Step 2
Attach the network ends of your two 75-ohm coaxial cables to your external T3 equipment as follows:
•
Attach the coaxial cable from the PA-MC-T3-EC TX port to the RX port on your external T3
equipment.
•
Attach the coaxial cable from the PA-MC-T3-EC RX port to the TX port on your external T3
equipment.
This completes the procedure for attaching 75-ohm coaxial cables on the PA-MC-T3-EC.
1
To RX port on external T3 equipment
3
BNC cables
2
To TX port on external T3 equipment
158058
1
3
2
ENABLED C/A
A/L
C/A
A/L
PA-MC-2T3-EC
TX
0
RX
TX
RX
1