8-29
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
OL-23069-06
Appendix 8 Managing the Switch Hardware
Reloading Modules
Power Usage Summary:
--------------------
Power Supply redundancy mode (configured) Redundant
Power Supply redundancy mode (operational) Redundant
Total Power Capacity (based on configured mode) 9000 W
Total Power of all Inputs (cumulative) 18000 W
Total Power Output (actual draw) 2259 W
Total Power Allocated (budget) 4750 W
Total Power Available for additional modules 4250 W
switch#
Reloading Modules
You can reload the entire switch, reset specific modules in the switch, or reload the image on specific
modules in the switch.
This section includes the following topics:
•
Reloading the Switch, page 8-29
•
Power Cycling Modules, page 8-29
Reloading the Switch
To reload the switch, use the
reload
command without any options. When you use this command, you
reboot the switch.
Note
If you need to use the
reload
command, be sure to save the running configuration by using the
copy
running-config startup-config
command beforehand.
Power Cycling Modules
To power cycle any module, follow these steps:
Step 1
Identify the module that needs to be reset.
Step 2
Reset the identified module by entering the
reload module
command. This command power cycles the
selected module.
switch#
reload module
number
The
number
indicates the slot in which the identified module resides.
Caution
Reloading a module disrupts traffic through the module.
Summary of Contents for Nexus 7004
Page 12: ...Contents xii Cisco Nexus 7000 Series Hardware Installation and Reference Guide OL 23069 07 ...
Page 19: ... xix Cisco Nexus 7000 Series Hardware Installation and Reference Guide OL 23069 07 ...
Page 22: ... xxii Cisco Nexus 7000 Series Hardware Installation and Reference Guide OL 23069 07 ...