41-27
Cisco ME 3400 Ethernet Access Switch Software Configuration Guide
OL-9639-07
Chapter 41 Configuring Ethernet OAM, CFM, and E-LMI
Configuring E-LMI
Configuring the OAM Manager
Beginning in privileged EXEC mode, follow these steps to configure OAM manager on a PE switch:
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
ethernet cfm domain
domain-name
level
level-id
Define a CFM domain, set the domain level, and enter
ethernet-cfm configuration mode for the domain. The
maintenance level number range is 0 to 7.
Step 3
service
csi-id
vlan
vlan-id
Define a universally unique customer service instance
(CSI) and VLAN ID within the maintenance domain.
•
csi-id
—a string of no more than 100 characters that
identifies the CSI.
•
vlan-id
—VLAN range is from 1 to 4095. You cannot
use the same VLAN ID for more than one domain at
the same level.
Step 4
exit
Return to global configuration mode.
Step 5
ethernet evc
evc-id
Define an Ethernet virtual connection (evc), and enter evc
configuration mode. The identifier can be up to 100
characters in length.
Step 6
oam protocol cfm svlan
vlan-id
domain
domain-name
Configure the EVC OAM protocol as CFM, and identify
the service provider VLAN-ID (S-VLAN-ID) for the CFM
domain maintenance level as configured in Steps 2 and 3.
Note
If the CFM domain does not exist, the command is
rejected, and an error message appears.
Step 7
uni count
value
(Optional) Set the UNI count for the EVC. The range is 2
to 1024; the default is 2.
If the command is not entered, the service defaults to a
point-to-point service. If you enter a value of 2, you have
the option to select point-to-multipoint service. If you
configure a value of 3 or greater, the service is
point-to-multipoint.
Note
You should know the correct number of
maintenance end points in the domain. If you enter
a value greater than the actual number of end
points, the UNI status will show as partially active
even if all end points are up; if you enter a uni count
less than the actual number of end points, status
might show as active, even if all end points are not
up.
Step 8
exit
Return to global configuration mode.
Step 9
Repeat Steps 2 to 5 for other CFM domains that you want OAM manager to monitor.
Step 10
interface
interface-id
Specify a physical interface connected to the CE device,
and enter interface configuration mode.
Summary of Contents for ME 3400 Series
Page 40: ...Contents xl Cisco ME 3400 Ethernet Access Switch Software Configuration Guide OL 9639 07 ...
Page 44: ...xliv Cisco ME 3400 Ethernet Access Switch Software Configuration Guide OL 9639 07 Preface ...
Page 1138: ...Index IN 52 Cisco ME 3400 Ethernet Access Switch Software Configuration Guide OL 9639 07 ...